Working principle of straight line is just like the slide rheostat, it used as a divider, displacement sensor
Displacement sensor
It was based on the relative output voltage to present the actually measured position by position. Work on this device has the following requirements:
1, if the ruler has been used for a long time, and the seal has been aging, at the same time with many impurities, and the mixture of water and oil will seriously affect the contact resistance of brush, such meetings make pumping in digital display. This time can say linear displacement transducer electronic feet has been damaged, need to change.
2, if the power supply capacity is small, there will be a lot of circumstances, so the power supply needs to have sufficient capacity. Then, capacity is insufficient, will cause the following situation: melt the games keep the clamping electronic scale transformation, there are fluctuations, or clamping games make plastic electronic scale showed fluctuations, causing measurement error is large. If the solenoid drive power stems from a linear displacement transducer power supply together at the same time, more prone to the above situation, situation serious when measured with a multimeter voltage profile can even to voltage fluctuations. If this is not because of the high frequency interference, electrostatic interference or neutral aren't good enough, then it is possible that the power supply of the power is too small.
3, frequency modulation interference and electrostatic interference are likely to make linear displacement transducer electronic scale display of digital pulse. Displacement sensor
Displacement sensor
Electronic scale signal lines and equipment of high voltage lines to separate trough. Electronic scale must be mandatory use of ground support, and at the same time make electronic ruler of shell contact with the ground well. Signal lines need to use the shielded wire and electric box should be with a shielded wire grounding.
If there is a high frequency interference, usually using a multimeter voltage measurements will show normal, but the display number is beating continuously; And electrostatic interference, the scenario is the same as high frequency interference. To prove whether electrostatic interference, to use a power cord to electronic scale block screw machine with some metal short pick up is ok, as long as a sub, electrostatic interference can immediately eliminate. But if you want to eliminate the high frequency interference is hard to use the above methods, variable frequency saver and machine hand often appear high frequency interference, so you can try to use stop section of high frequency electrical or mechanical methods to verify whether high frequency interference.
4, if the linear displacement transducer electronic scale in the process of work, at a certain point of display data is beating regularly, or when data is not shown, appear this kind of circumstance, there is need to check the cable insulation damage phenomenon, and contact with machine shell very regularly and cause of short circuit.
5, power supply voltage must be stable, the industry of the voltage need to conform to the stability of plus or minus 0.1 [%], for example, the reference voltage is 10 V, can allow a plus or minus 0.01 V fluctuation change, if not, it could cause according to trap fluctuations. Displacement sensor
Displacement sensor
But if this time the display of the width of fluctuation in no more than the range of the fluctuation of voltage fluctuation, then electronic scale is normal.
6, install linear displacement transducer to neutral need is very good, but the degree of parallelism can be allowed to have the error of + / - 0.5 mm, the error of plus or minus 12 ° Angle can allow. But if the parallelism error and Angle error is big, so there will be a display of digital pulse. Then appear such circumstance, must adjust parallelism and point of view.
7, in the process of connection, must be more careful, electronic foot three line is not wrong, you can't switch the power cord and output. If the above line wrong, can appear linear error is large, it is difficult to control, control accuracy will become is very poor, and shows that it is easy to appear beat phenomenon, and so on.